1.15.2.1 Safety warnings review the structure
Equipment for building-in. The requirements for fire enclosure must be evaluated in the end
product
The clearance and creepage current distances required by the end product must be withheld when
the module is installed
The cooling of the end product shall not negatively be influenced by the installation of the module
Excessive sound pressure from earphones and headphones can cause hearing loss
No natural rubbers, no hygroscopic materials nor materials containing asbestos are employed
1.15.2.2 Declaration of conformity
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
this device may not cause harmful interference
this device must accept any interference received, including interference that may cause
undesired operation
Radiofrequency radiation exposure Information: this equipment complies with FCC radiation
exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions.
This equipment should be installed and operated with a minimum distance of 20 cm between the
radiator and the body of the user or nearby persons. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter except in accordance with FCC
procedures and as authorized in the module certification filing.
The gain of the system antenna(s) used for LISA-U200 (i.e. the combined transmission line,
connector, cable losses and radiating element gain) must not exceed 4.25 dBi (in 850 MHz, i.e.
GSM 850 or UMTS FDD-5 band), 7.30 dBi (in 1700 MHz, i.e. AWS or UMTS FDD-4 band) and 2.74 dBi
(in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating
configurations.
The gain of the system antenna(s) used for LISA-U201 (i.e. the combined transmission line,
connector, cable losses and radiating element gain) must not exceed 4.0 dBi (in 850 MHz, i.e. GSM
850 or UMTS FDD-5 band) and 3.5 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile
and fixed or mobile operating configurations.
The gain of the system antenna(s) used for LISA-U230 (i.e. the combined transmission line,
connector, cable losses and radiating element gain) must not exceed 4.78 dBi (in 850 MHz, i.e.
GSM 850 or UMTS FDD-5 band), 7.55 dBi (in 1700 MHz, i.e. AWS or UMTS FDD-4 band) and
3.95 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating
configurations.
The gain of the system antenna(s) used for LISA-U260 and LISA-U270 (i.e. the combined
transmission line, connector, cable losses and radiating element gain) must not exceed 4.88 dBi
(in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band) and 4.08 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS
FDD-2 band) for mobile and fixed or mobile operating configurations.
1.15.2.3 Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that
are not expressly approved by u-blox could void the user's authority to operate the equipment.
Manufacturers of mobile or fixed devices incorporating the LISA-U2 modules are authorized to use
the FCC Grants of the LISA-U2 modules for their own final products according to the conditions