User's Manual

LILY-W1 series - Data Sheet
UBX-15000203 - R04 Early Production Information Electrical specifications
Page 15 of 38
4 Electrical specifications
Stressing the device above one or more of the ratings listed in the Absolute maximum rating
section may cause permanent damage. These are stress ratings only. Operating the module at
these or at any conditions other than those specified in the Operating conditions section of this
document should be avoided. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
Operating condition ranges define those limits within which the functionality of the device is guaranteed.
Where application information is given, it is advisory only and does not form part of the specification.
4.1 Absolute maximum ratings
Symbol
Description
Condition
Min
Max
Unit
VCC
Module supply voltage
Input DC voltage at VCC pin
-
4.0
V
VCC_IO
IO voltage supply
Input DC voltage at VCC_IO pin
1.8 V mode
-
2.2
V
3.3 V mode
4.0
V
Table 5: Absolute maximum ratings
4.1.1 Maximum ESD ratings
Parameter
Maximum
Unit
Remarks
ESD immunity
±6000
V
Indirect discharge to a coupling plane
IEN 61000-4-2
ESD immunity for ANT pin
±6000
V
Contact Discharge according to IEC 61000-4-2
ESD sensitivity for ANT pin
300
V
Human Body Model (HBM) according to JESD22-A114
Class 1A
ESD sensitivity for all pins except ANT pin
±1000
V
Human Body Model (HBM) according to JESD22-A114
Class 1C
Table 6: Maximum ESD ratings
4.2 Operating conditions
4.2.1 Temperature range
Parameter
Minimum
Maximum
Unit
Storage temperature
-40
+85
°C
Operating temperature
-40
+85
°C
Table 7: Temperature range
4.2.2 Power supply
Read the safety notes in section Guidelines for Efficient and Safe Use before using the modules.
Symbol
Parameter
Min.
Typ
Max.
Unit
VCC
Supply voltage
3.00
3.30
3.60
V
VCC_IO
Digital IO supply voltage
1.8 V mode
1.62
1.80
1.98
V
3.3 V mode
3.00
3.30
3.60
V
Table 8: Power supply voltage