4 Electrical specification
⚠ Operating JODY-W2 modules above any of the absolute maximum ratings shown in Table 16 can
cause permanent damage to the device. Extended exposure to conditions outside of the absolute
maximum ratings can also affect the device reliability.
4.1 Absolute maximum ratings
Symbol Description Min. Max. Units
VBAT Power supply voltage -0.3 7.0 V
VIO I/O supply voltage 1.8V/3.3V - 4.0 V
1V8 Analog power supply voltage 1.8V - 1.98 V
T
STORAGE
Storage temperature -40 +105
3
ºC
Table 16: Absolute maximum ratings
⚠ The product is not protected against overvoltage or reversed voltages. Voltage spikes exceeding
the power supply voltage specification, given in table above, must be limited to values within the
specified boundaries by using appropriate protection devices.
4.2 Operating conditions
Symbol Parameter Min. Typ Max. Units
VBAT Power supply voltage 2.8 - 5.5 V
VIO I/O supply voltage 1.8V 1.67 - 1.92 V
I/O supply voltage 3.3V 3.07 - 3.53 V
1V8 Analog power supply voltage 1.8V 1.71 1.8 1.89 V
T
A
Ambient operating temperature
JODY-W263-00A/B
-40 - +85 ºC
Ambient operating temperature
JODY-W263-01A
-40 - +105 ºC
Ripple Noise
Peak-to-peak voltage ripple on all supply lines. - - 10 mV
Table 17: Operating conditions
☞ Operating condition ranges specified in Table 17 define the limits within which the
functionality of the device is guaranteed.
3
Qualification pending