User's Manual
24 || G7 TECHNICAL USER MANUAL
CONFIGURATION MODES
Conguration modes are customized in the G7 conguration prole on Blackline Live. Each
prole supports up to a total of ve ‘modes’ . These modes allow G7 to temporarily change
its behavior for dierent situations, and can be turned on and o through G7’s interface.
AVAILABLE MODES
Normal
This mode is the configuration you determine for everyday operation. G7 will operate
using this mode as a default.
Pre-entry
Pre-entry mode is used before entering a space that could potentially contain
dangerous gas. This mode can be used with or without a pump cartridge, which will
actively draw surrounding air to its sensors and test gas levels.
SCBA
This mode is meant to be used when the device user is wearing a self-contained or
supplied air breathing apparatus (SCBA/SABA) and is entering an area that is known to
have high gas levels.
Leak check
Leak check mode can be used when checking for gas leaks in a particular area. This
mode – like pre-entry mode – can be used with or without a pump cartridge.
High risk
This mode is unique in that it is meant for general high-risk situations, such as an
evacuation or travelling through a dangerous area. Unlike the other modes, you will
never be timed out and must exit it manually.
Pump run
This mode is unique in that a multi-gas pump cartridge is required to use this mode, and
it runs the pump continuously – such as for use in a hole-watch situation. Unlike
the other modes, you will never be timed out and must exit it manually.
ENTERING A MODE
How do I enter a mode?
To use a mode, it must first be enabled in G7’s configuration profile on
Blackline Live. Entering a mode can be done from G7’s main menu or main status screen.