4 Electrical specifications
Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating
section may cause permanent damage. These are stress ratings only. Operating the module at
these or at any conditions other than those specified in the Operating Conditions sections
(section 4.2) of the specification should be avoided. Exposure to Absolute Maximum Rating
conditions for extended periods may affect device reliability.
Operating condition ranges define those limits within which the functionality of the device is guaranteed.
Where application information is given, it is advisory only and does not form part of the specification.
4.1 Absolute maximum rating
Limiting values given below are in accordance with the Absolute Maximum Rating System (IEC 134).
Symbol
Description
Condition
Min.
Max.
Unit
VCC
Module supply voltage
Input DC voltage at VCC pin
0.30
5.00
V
V_BCKP
RTC supply voltage
Input DC voltage at V_BCKP pin
0.15
2.00
V
VUSB_DET
USB detection pin
Input DC voltage at VUSB_DET pin
0.15
5.50
V
USB
USB D+/D- pins
Input DC voltage at USB_D+ and USB_D- pins
1.00
5.50
V
GDI
Generic digital interfaces
Input DC voltage at Generic digital interfaces pins
0.30
3.60
V
HSIC
HSIC interface
Input DC voltage at HSIC interface pins
0.30
3.60
V
DDC
DDC interface
Input DC voltage at DDC interface pins
0.30
3.60
V
SIM
SIM interface
Input DC voltage at SIM interface pins
0.30
3.60
V
ERS
External reset signal
Input DC voltage at RESET_N pin
0.30
2.10
V
POS
Power-on input
Input DC voltage at PWR_ON pin
0.30
2.10
V
Tstg
Storage Temperature
40
85
°C
Table 6: Absolute maximum ratings
The product is not protected against overvoltage or reversed voltages. If necessary, voltage
spikes exceeding the power supply voltage specification, given in table above, must be limited
to values within the specified boundaries by using appropriate protection devices.
4.1.1 Maximum ESD
Parameter
Min
Typical
Max
Unit
Remarks
ESD sensitivity for all pins
except ANT1 / ANT2 pins
1000
V
Human Body Model according to JESD22-A114
ESD sensitivity for ANT1 / ANT2 pins
1000
V
Human Body Model according to JESD22-A114
Table 7: Maximum ESD ratings
u-blox cellular modules are Electrostatic Sensitive Devices and require special precautions when