User's Manual

Table Of Contents
TOBY-R2 series - Data Sheet
UBX-16005785 - R06 Pin definition
Page 21 of 41
No
Name
Power
domain
I/O
Description
Remarks
69
GND
GND
N/A
Ground
All GND pins must be connected to ground.
70
VCC
VCC
I
Module supply input
Supply for BB part on TOBY-R200.
Supply for BB part and PA on TOBY-R202.
All VCC pins must be connected to external supply.
See sections 4.2.2 / 4.2.3 for detailed electrical specs.
71
VCC
VCC
I
Module supply input
Supply for PA on TOBY-R200.
Supply for BB part and PA on TOBY-R202.
All VCC pins must be connected to external supply.
See sections 4.2.2 / 4.2.3 for detailed electrical specs.
72
VCC
VCC
I
Module supply input
Supply for PA on TOBY-R200.
Supply for BB part and PA on TOBY-R202.
All VCC pins must be connected to external supply.
See sections 4.2.2 / 4.2.3 for detailed electrical specs.
73
GND
GND
N/A
Ground
All GND pins must be connected to ground.
74
GND
GND
N/A
Ground
All GND pins must be connected to ground.
75
ANT_DET
ADC
I
Antenna detection
Antenna presence detection function.
See section 4.2.7 for detailed electrical specs.
76
GND
GND
N/A
Ground
All GND pins must be connected to ground.
77
RSVD
-
N/A
RESERVED pin
Leave unconnected.
78
GND
GND
N/A
Ground
All GND pins must be connected to ground.
79
GND
GND
N/A
Ground
All GND pins must be connected to ground.
80
GND
GND
N/A
Ground
All GND pins must be connected to ground.
81
ANT1
ANT
I/O
Primary antenna
50 nominal characteristic impedance.
Main Tx / Rx antenna interface.
See sections 4.2.4 / 4.2.5 / 4.2.6 for details.
82
GND
GND
N/A
Ground
All GND pins must be connected to ground.
83
GND
GND
N/A
Ground
All GND pins must be connected to ground.
84
RSVD
-
N/A
RESERVED pin
Leave unconnected.
85
GND
GND
N/A
Ground
All GND pins must be connected to ground.
86
GND
GND
N/A
Ground
All GND pins must be connected to ground.
87
ANT2
ANT
I
Secondary antenna
50 nominal characteristic impedance
Rx only for Down-Link Rx diversity.
See section 4.2.4 for details.
88
GND
GND
N/A
Ground
All GND pins must be connected to ground.
89
GND
GND
N/A
Ground
All GND pins must be connected to ground.
90
GND
GND
N/A
Ground
All GND pins must be connected to ground.
91
RSVD
-
N/A
RESERVED pin
Leave unconnected.
92
GND
GND
N/A
Ground
All GND pins must be connected to ground.
93-152
GND
GND
N/A
Ground
All GND pins must be connected to ground.
Table 5: TOBY-R2 series pin-out
For more information about the pin-out, see the TOBY-R2 series System Integration Manual [2].
See Appendix A for an explanation of abbreviations and terms used.