I.5.4 DC Voltage
Alert - when crossing DC Voltage above the set value (≥50V) the numeric value turns red
and the buzzer beeps
Block - when crossing DC Voltage above critical value (≥55V ) it declares "Warning" on
the display and it blocks the LDMOS (Inhibit -5V), it turns the coax relay off and it blocks
the PTT.
In order to restore operation it is necessary to “Restart confirm “Warning“ and return to
the Display operation
Alert
I.5.5 Drain Current
Alert - when crossing Current above the set value (≥31A) the numeric value appears red
and the buzzer beeps
Block - when crossing Current above the critical value (≥35A ) it declares "Warning" on
the display and it blocks the LDMOS (Inhibit -5V), it turns the coax relay off and it blocks
the PTT.
In order to restore the operation it is necessary to “Restart confirm “Warning“ and
return to the Display operation
Alert