Phau Ntawv Qhia

_______________________________________________________________________________________
Page 7 of 10 VH Electronics Slovakia www.vhelectronics.sk
I.5.2 Reflected Power REF
Alert - when crossing PWR above the set value (≥100W) it gets into a red bargraph, the
numeric value turns red and the buzzer beeps
Block - when crossing REF above critical value (≥110W) it declares "Warning" on the
display and it blocks the LDMOS (Inhibit -5V), it turns the coax relay off and it blocks the
PTT.
In order to restore operation it is necessary to “Restart confirm “Warning“ and return to
the Display operation
Alert
I.5.3 Temperature
Alert - when crossing the temperature above the set value (≥65°C) it gets into a red
bargraph, the numeric value turns red and the buzzer beeps
Block - when crossing PWR above critical value (≥70°C ) it declares "Warning" on the
display and it blocks the LDMOS (Inhibit -5V), it turns the coax relay off and it blocks the
PTT.
In order to restore operation it is necessary to “Restart confirm “Warning“ and return to
the Display operation
Alert