3. COMPOSITION/INFORMATION ON HAZARDOUS INGREDIENTS
Ingredient name
CAS #
EINECS
Content
(%)
ACGIH
TLV-TWA
(mg/m
3)
OSHA PEL-8h
TWA
(mg dust/m3)
T: total, R: Respirable
LD
50
LC50
GHS Classification
Silica, Quartz
CAS#
14808-60-7
EINECS#
238-878-4
15-40
(Respirable:
<0.003)
0.025
30/(%SiO
2
+2) (T)
10/(%SiO2+2) (R)
500mg/kg (oral, rat)
Not Available
STOT SE 2 H373
Calcium
Hydroxide
CAS#
1305-62-0
EINECS#
215-137-3
1-5
5
15 (T)
5 (R)
7340mg/kg (oral,
rat)
Not Available
Skin Irrt. 2 H315
Eye Dam. 1 H318
STOT SE 3 H335
4. FIRST AID MEASURES
When contacting a physician, take this SDS with you.
Eyes:
• Do not rub eye(s) as additional cornea damage is possible by mechanical stress.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue
rinsing for at least 60 minutes. Immediately call a POISON CENTER or doctor/physician.
Skin:
• For dry product, remove and rinse abundantly with water.
• For wet product, wash skin with water.
• Remove contaminated clothing, footwear, watches, etc. and clean thoroughly before re-using them.
• Seek medical treatment in all cases of irritation or burns.
Ingestion:
• Do not induce vomiting.
• If person is conscious, wash out mouth with water and give plenty of water to drink.
• Get immediate medical attention or contact anti poison center.
Inhalation:
• Remove to fresh air and at rest and in a position of comfortable breathing.
• If breathing has stopped, institute artificial respiration.
• Get medical attention if discomfort remains.
Most Important Symptoms and Effects both Acute and Delayed
Acute: Corrosive to skin, eyes and respiratory tract. Exposure may produce allergic reaction.
Delayed: Long term exposure to dust may result in lung damage.
5. FIREFIGHTING MEASURES
Flammability: Noncombustible
Means of Extinction: Water, Fog, Alcohol-Resistant Foam, Dry Chemical or Carbon Dioxide (CO2)
Flashpoint and Method: Non-combustible, >200F
Autoignition Temperature: Not Applicable
Fire and Explosion Data: Not Applicable
Hazardous Combustion Products: Not Applicable
Fire Fighting Instructions: Firefighters should wear self-contained breathing apparatus and full protective gear. Product
reacts with water and creates heat.