Specification
PART 1 – GENERAL
1.1 Section Includes
A. Self-adhering Flashing (TYPAR Flashing BA, TYPAR Flashing Flex and TYPAR Flashing RA).
B. Primers.
C. Fasteners.
1.2 References
A. ASTM International
1. ASTM D-903, Standard Test Method for Peel or Stripping Strength of adhesive bonds.
2. ASTM D –2533, Standard practice for Twisting Load-Strain Properties.
3. ASTM D-1970, Standard Specification for Self-Adhesion polymer modified bituminous sheet
materials.
1.3 Submittals:
A. Product Data: Submit manufacturer current technical literature for each type of product.
B. Submit copies of test results showing performance characteristics equaling or exceeding those specified.
1.4 Quality Assurance
A. Qualifications
1. Installer shall have documented successful experience with installation of TYPAR Flashing products.
2. Installation shall be in accordance with manufacturer’s installation guidelines and recommendations.
PART 2 - PRODUCTS
2.1 Manufacturer
A. Avintiv, Inc., a Berry Plastics Company, 70 Old Hickory Blvd, Old Hickory, TN 37138; 800-284-2780; www.
TYPAR.com
2.2 Materials
A. Self-adhering/straight flashing
a. Description
i. Face material composition: smooth polypropylene barrier
ii. Face color: gray
iii. Adhesive composition: butyl adhesive
iv. Thickness: 15mil
v. Release liner: siliconized paper
vi. Dimensions: 4 in. X 75 ft. 6 in. X 75 ft. 9 in. X 75 ft.
B. Self-adhering flashing flex
a. Description
i. Face material composition: Conformable textured polyolefin
ii. Face color: dark gray
iii. Adhesive composition: butyl adhesive
iv. Thickness: 60mil
v. Release liner: siliconized paper
vi. Dimensions: 6 in. X 75 ft. 9 in. X 75 ft.
C. Performance characterizations
a. Low temp Flex ASTM D-903 PASS
b. Nail sealability ASTM D-1970 PASS
c. Tensile strength ASTM D-2523 PASS
2.3 Accessories
A. Primer: Use 3M™ Super77™ or equal
B. Seam tape: TYPAR construction
C. Fastener: Fastener is dependent on substrate construction
D. Sealant: Must comply with ASTM C920 elastomeric polymer sealant
PART 3 – EXECUTION
3.1 Examination
A. Verify substrate and surface conditions are in accordance with the flashing manufacturer’s recommendation.
NOTE – Flashing manufacturer recommends weather barrier be installed prior to the installation of the
windows.
3.2 Installation
A. Follow the TYPAR flashing installation procedures
3.3 Protection
A. Protect installed flashing from damage during construction
TYPAR
®
Construction Tape Three Part Specs:
SPECIFICATIONS:
TYPAR
®
CONSTRUCTION TAPE
Three Part Specifications
MADE IN USA. ICC #ESR-1404 • CCMC #12884-R • CCMC #12892-R
Please visit typar.com for installation instructions and warranty information
Avintiv, Inc., 70 Old Hickory Blvd., Old Hickory, TN 37138 USA, typar.com