Specification
Made in USA. © 2017, Berry Plastics Corporation.
TYPAR
®
is a registered trademark of Berry Plastics Corporation or its affiliate.
Please visit TYPAR.com for installation instructions and warranty information.
Building Wraps | Flashings | Construction Tape | Fasteners
THREE-PART SPECIFICATIONS
TYPAR
®
ALL-TEMPERATURE FLASHING
3396
PART 1. GENERAL
1.1 Section Includes
A. Self-adhering Flashing: TYPAR All-Temperature Flashing
B. Primers
C. Fasteners
1.2 References
A. ASTM International
1 . ASTM D-3330-04, Standard test method for peel or stripping strength of adhesive bonds
2. ASTM C-765, Standard practice for cold pliability
3. ASTM D-1970, Standard specification for self-adhesion polymer modified bituminous sheet materials
1.3 Submittals
A. Product Data: Submit manufacturer current technical literature for each type of product
B. Submit copies of test results showing performance characteristics equaling or exceeding those specified
1.4 Quality Assurance
A. Qualifications
1 . Installer shall have documented successful experience with installation of TYPAR Flashing products
2. Installation shall be in accordance with manufacturer’s installation guidelines and recommendations
PART 2. PRODUCTS
2.1 Manufacturer
A. Berry Plastics, 70 Old Hickory Blvd, Old Hickory, TN 37138, +1 615-847-7000; www.TYPAR.com
2.2 Materials
A. Self-adhering/straight flashing
1 . Description
i. Face material composition: polypropylene barrier
ii. Face color: gray
iii. Adhesive composition: block copolymer
iv. Thickness: 16mil
v. Release liner: polyfilm
vi. Dimensions: 4in x 25ft; 4in x 75ft; 6in x 75ft; 9in x 75ft; 12in x 75ft
B. Performance characterizations
1 . Low temp pliability ASTM C-765 PASS
2. Nail sealability ASTM D-1970 PASS
3. Tensile strength ASTM D-5034-95 PASS
4. Peel adhesion ASTM D-3330-04 PASS
2.3 Assessories
A. Primer: Use 3M
™
S up e r7 7
™
or equal
B. Seam tape: TYPAR construction
C. Fastener: Fastener is dependent on substrate construction
D. Sealant: Must comply with ASTM C920 elastomeric polymer sealant
PART 3. EXECUTION
3.1 Examination
A. Verify substrate and surface conditions are in accordance with the flashing manufacturer’s recommendation
NOTE – Flashing manufacturer recommends weather barrier be installed prior to the installation of the windows
3.2 Installation
A. Follow the TYPAR flashing installation procedures
3.3 Protection
A. Protect installed flashing from damage during construction