INNOVATION AND INSPIRATION ON FIRE™ TWIN EAGLES VENT HOOD INSTALLATION INSTRUCTIONS FOR RESIDENTIAL USE ONLY.
A SPECIAL MESSAGE TO OUR CUSTOMERS... Congratulations on the purchase of your Twin Eagles Vent Hood! Our products are engineered for precision and designed for style. Each Twin Eagles Vent Hood is manufactured in the USA at our own state of the art facility in California. This manual will give you easy to follow instructions for installing, operating and maintaining your Vent Hood. We recommend reading this manual before your first use to ensure safety, proper care and operation.
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS GETTING STARTED ELECTRICAL REQUIREMENTS VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS TOP EXHAUST REAR EXHAUST MOUNTING THE TRANSITION OUTSIDE PATIO OR LANAI INSTALLATION BAFFLE FILTER INSTALLATION, USE, AND CARE TEVH-C EXPLODED VIEW TEVH-C REPLACEMENT PARTS LIST TEVH-C WIRING DIAGRAM WARRANTY HOW TO OBTAIN SERVICE CUSTOMER CARE 1 Please record the product information below and 2 refer to it when contacting Twin Eagles.
IMPORTANT SAFETY INSTRUCTIONS: Read this manual carefully and completely before using your Vent Hood to ensure proper operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard and/ or other injury. WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B.
GETTING STARTED: 1. Remove all packaging materials, labels and protective plastic film. DO NOT LEAVE UNIT IN THE SUN WITH PROTECTIVE PLASTIC FILM ON FOR AN EXTENDED PERIOD OF TIME AS IT WILL BECOME DIFFICULT TO REMOVE. 2. Check to ensure all Vent Hood accessories listed below are included. 3. Assemble parts as per assembly instructions. 4. Fill out Warranty Registration Card and mail it to the indicated address, or register online. See page 17.
ELECTRICAL REQUIREMENTS: The appliance should only be taken apart by a qualified technician, or electrical shock may occur. It is rated at 120V, 5.4 Amps, 60Hz. REMINDER: Keep any electrical supply cord away from any heated features. Unit comes with three-pronged power cord pre-installed. Vent hood must be plugged into a GFCI protected branch circuit. Suitable for use in damp locations when installed in a GFCI protected branch circuit. NOTE: Ventilator requires a dedicated 15 AMP Power Supply.
VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS: NOTE: The hood is of sufficient weight that two installers are recommended to prevent injury or damage to the hood in handling. Before starting the installation, you must identify if the installation will be a rear exhaust or top exhaust installation. ! UNIT MUST BE VENTED TO THE OUTSIDE OF THE BUILDING. ! Begin the installation by removing the appropriate knock-out that will provide the top or rear exhaust point. See FIG 1A for knock-out locations.
VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS -cont: Installation of the Vent Hood should also take into account the unit that the Vent Hood is to be installed above. For best ventilation of smoke and heat, make sure the vent hoof is centered above the appliance and a minimum of 36 inches above the cooking surface. Refer back to the appliance manual to be sure distances and clearances to combustible construction are maintained.
TOP EXHAUST FIG 2 BOTTOM VIEW OF CABINET WIRING ACCESS HOOD WIDTH DIM A 36” 8 3/8” 48” 17 1/2” 60” 23 7/16” BACK WALL ADD FURRING STRIPS TO PROVIDE AN EVEN BOTTOM SURFACE FOR THE HOOD MOUNTING. FIG 3 REMOVE KNOCK OUT # 2 B FIG 4 VERTICAL DISCHARGE A 12” 10” DUCT TO DISCHARGE W/ ROOF OF WALL CAP TRANSITION ROTATE INTO POSITION & SECURE WITH 2 SCREWS 3” ALL HOODS 18” 30” 10” DISCHARGE WITH TRANSITION WILL BE ON THE CENTER LINE OF HOOD WIDTH AND ON CENTER LIE OF 12” DIMENSION.
REAR EXHAUST FIG 5 BOTTOM VIEW OF CABINET HOOD WIDTH DIM A 36” 8 3/8” 48” 17 1/2” 60” 23 7/16” WIRING ACCESS BACK WALL ADD FURRING STRIPS TO PROVIDE AN EVEN BOTTOM SURFACE FOR THE HOOD MOUNTING. FIG 7 FIG 6 A ROTATE INTO POSITION & SECURE WITH 2 SCREWS ROUTE TO OUTSIDE WITH WALL CAP B 7 | www.twineaglesgrills.com SECURE TRANSITION TO HOOD USING #10 SHEET METAL SCREWS. TAPE ALL JOINTS AND SEAMS.
FIG 8 REAR EXHAUST A A = CENTER OF ROUND DUCT USING TWIN EAGLES TRANSITION CUT HOLE IN DRYWALL TO ACCEPT TRANSITION MOUNTING THE TRANSITION: FIG 9 TOP EXHAUST FIG 10 REAR EXHAUST #10-24 METAL CUTTING SCREWS #10-24 METAL CUTTING SCREWS X4 X4 Twin eagles Service (562) 263-3600 | 8
OUTSIDE PATIO or LANAI INSTALLATION Construction methods and installation shall comply with all local building codes. Internal ducting shall be sealed using outdoor rated metal tape. The Twin Eagles hood with stainless steel canopy is approved for installation in an outside patio or lanai area if the area is covered with a protective roof over the hood (wall style hoods are to be also mounted to a solid protective rear wall) and installed with a GFCI protected branch circuit.
FIG 10 ROOF CAP 12” B A A * * = TOTAL OVERALL WIDTH WITH HOOD A = 42” MINIMUM FRONT VIEW TOP EXHAUST B = 30” MINIMUM SIDE VIEW Twin eagles Service (562) 263-3600 | 10
BAFFLE FILTER INSTALLATION, USE AND CARE INSTALLER: Please leave these installation instructions with unit for the owner. 1. Remove all packaging and the productive plastic covering from filters. 2. Grasp the filter by the center baffle, see FIG 11, with the spring end facing you and the grease collector channel is facing down and toward the rear of the hood.
TEVH-C EXPLODED VIEW * - #12 AND #13 SOLD SEPARATELY Twin eagles Service (562) 263-3600 | 12
TEVH-C REPLACEMENT PARTS LIST ITEM NO.
N LEFT L I GHT G BLK 18 GA WHT 18 GA WHT 18 GA GRN 18 GA WHT 18 GA ROT ARY L I GHT S WI T CH BLK 18 GA L1 POWER S UPPL Y 4 B 3 1 A 2 WHT 18 GA BLK 12 GA BLK 18 GA W 18 GA BLK 18 GA R 18 GA BLU 18 GA BLK 18 GA BLK 18 GA 1 4 2 6 3 -S PD ROT ARY S WI T CH WHT 18 GA R 18 GA BLU 18 GA HOOD RECEPT ACL E BOX MED HI LO RI GHT L I GHT WHT 18 GA WHT 18 GA BL OWER MOT OR WHT 18 GA WHT 18 GA TEVH-C WIRING DIAGRAM Twin eagles Service (562) 263-3600 | 14
TEVH-C WARRANTY LIMITED TWO YEAR WARRANTY: Twin Eagles warrants the Vent Hood to be free from defects in materials and workmanship under normal residential use for a period of two years from the original date of purchase. The actual part will be repaired or replaced, free of charge, with the owner paying for all other costs including labor, shipping and handling.
SERVICE HOW TO OBTAIN For service, please contact your Twin Eagles dealer or call Twin Eagles direct at (562) 263-3600 or fax (562) 802-3391 Mailing address: Twin Eagles, Inc. 13259 East 166th Street Cerritos, CA 90703 Visit us at www.twineaglesgrills.com Please provide: • Model number • Serial Number (located on the inner left hand face of the vent hood.