User guide

Manual 0-4678 4-1 Operation
SECTION 4:
OPERATION
4.01 Front Control Panel
Overheating
Indicator
AC Power
Indicator
Air Error Indicator
Torch Switch
Latch Indicato
r
Torch Switc
h
Latch Butto
n
Air Set
Button
Air Vents
Work Lead
Connection
"On / Off"
Switch
Art # A-04386
Torch
Connection
I
O
115VAC
230VAC
8
10
12
14
10
11
12
13
14
15
17
18
19
20
21
22
23
24
25
A
35A
16
18
20
16
Current
Control Knob
A. Indicator Lamp
Power Indicator
Lights when primary power switch is turned
on.
TEMPERATURE Indicator
Indicator is normally OFF. Indicator is ON
when internal temperature exceeds normal
limits.
Air Error Indicator
This indicator lights and is accompanied by an
intermittent audible tone when there is not
enough air pressure to operate the power sup-
ply. Indicator is normally off.
NOTE
It is possible to have enough air pressure to op-
erate the power supply but not enough air flow
to operate the torch.
Torch Switch Latch Indicator
This indicator lights when the Torch Switch
Latch Button has been pressed for continuous
cutting.
B. Buttons
Torch Switch Latch Button
For continuous cutting performance. Depress
this button ( turn “On” ) while cutting with the
torch. Release the torch trigger and the torch
will continue to cut without depressing the torch
trigger.
Air Set Button
To adjust air pressure and to cool down heated
torch.
Art # A-04503
Air will flow from gap
next to shield cup.
C. Main Current Control Knob
To adjust cutting current. Turning clockwise in-
creases the cutting current and counter clock-
wise decreases the cutting current.
10
15
20
25
A
3
0
35
A
rt # A-04387
D. Primary Power Switch, ON / OFF
The power switch is located on the front panel.
Placing the primary power switch to the “ON”
position energizes the power source and acti-
vates the Power Indicator.
WARNING
When the power source is overloaded, the switch
turns to the OFF position automatically. DO
NOT TURN ON BY FORCE.