User guide

Manual 0-4678 3-1 Installation
SECTION 3:
INSTALLATION
3.01 Site Selection
Place in a clean and dry area.
Provide adequate ventilation and fresh air sup-
ply.
Ideal ambient temperature should not exceed
40°C / 104°F. Temperatures exceeding that may
diminish cutting capacity or quality.
The cutting machine must be placed on an even,
firm surface so that it stands firmly.
3.02 Electrical Input Connections
Input voltage is 230V ± 10%, 50/60 Hz single
phase.
CAUTION
Check your power source for correct voltage be-
fore plugging in or connecting the unit. The
primary power source, fuse, and any extension
cords used must conform to local electrical code
and the recommended circuit protection and wir-
ing requirements as specified in Section 2.0.
3.03 Compressed Air Connection
An air compressor is required and should be con-
nected to rear panel of power source by air hose.
Air pressure should be 75 psi (5.2 bar) (.52MPa)
and air should be dry and clean.
Air flow should be 400 scfh / 6.6 scfm (188.7 lpm)
minimum.
Connect
Air Here
Input
Power
Art # A-04485
DANGER
Do not cut in humid or wet surroundings.
Before you maintain or replace torch parts, wait
for the post flow air cycle (approximately 10 sec-
onds), to stop, then turn the machine off.
Always use original manufacturers parts. The use
of aftermarket parts could result in shorter parts
life and in unsatisfactory cutting results. Any war-
ranty claims would be waived.
NOTE
Repairs must be done by skilled and qualified
personnel only.