User guide

Manual 0-4686 3-3 Installation
3.03 Compressed Air Connection
An air compressor is required and should be con-
nected by an air hose to the air regulator on the
rear panel of the power supply .
Air flow should be 400 scfh / 6.6 scfm (188.7 lpm)
minimum.
Input Powe
r
Cable
C
onnect
A
ir Here
Art # A-04489
3.04 Torch
Make sure that the torch cable and torch switch
terminals are connected through the front panel.
Make sure the Work Cable is connected properly
through the front panel and the clamp to clean
work surface.
Before activating, turn torch away from yourself
and others.
DANGER
Do not cut in humid or wet surroundings.
Before you maintain or replace torch parts, wait
for the post flow air cycle (approximately 10 sec-
onds), to stop, then turn the machine off.
Always use original manufacturers parts. The use
of aftermarket parts could result in lower parts
life and in unsatisfactory cutting results. Any
warranty claims would be waived.
Recycle worn parts according to local require-
ments.
NOTE
Repairs must be done by skilled and qualified
personnel only.