User guide
Installation 3-2 Manual 0-4686
4. Connect the cord to the input power terminal block
as shown for single or three phase. Input connec-
tions must be connected oposite the red and the
black wires. The white wire is used for 3 Phase.
Check for secure connections to the block. All cord
installations require a ground wire connection to the
power supply chassis; refer to the power supply
upper horizontal panel for proper ground wire con-
nection location.
Art # A-04670-S
Negro
Blanco
Ro
jo
NO SE
USA
EnergĂa
de Entrada
Monofásico,
1 alambre
A
rt # A-04697
Black
White
Re
d
1 Phase
3 Wire
Input Power
A
rt # A-04652
Black
White
Re
d
3 Phase
Input Power
5. Provide a small amount of slack in the cord between
the terminal block and the through-hole protector.
Tighten the through-hole protector to the cord by
hand only. Do not overtighten or use a wrench.
For 230-Volt or 460-Volt Power Supplies Only:
6. Locate the input power bus bar block on the right
side of the power supply. Position the bars accord-
ing to the input power in use.
460V Input Power
230V Input Power
Bus Bars
Bus Bars
Art # A-04650
7. Reinstall the power supply covers. Tighten the hard-
ware securely; do not overtighten.










