User guide

CUTMASTER A40
3T-2 INSTALLATION Manual 0-4978
+12VDC
PCB4
AUTOMATION
INTERFACE PCB
}
OK-TO-MOVE
FULL FEATURED AUTOMATION INTERFACE PCB OPTION
(+)
}
To configure DIVIDED ARC VOLTS signal output
No jumper installed for ARC VOLTS /16.67
Jumper pins 1 & 2 for ARC VOLTS / 30
Jumper pins 2 & 3 for ARC VOLTS / 50
K1
To -V OUT 1
on PCB1
}
/START / STOP
**
}
DIVIDED ARC VOLTS
(+)
(-)
(W/ 100K IN SERIES (2))
(-)
*
ARC VOLTS
J1J1
1
2
3
4
5
6
7
8
J3J3
1
2
3
P10P10
1
2
3
4
5
6
7
8
E1E1
K1K1
J2J2
2
3
4
5
6
7
8
9
10
11
12
13
14
1
Art # A-09819_AB
3. Connect CNC to the power supply.
3T.03 SETTING UP AUTOMATION OR MACHINE TORCH
NOTE
An adapter is required to be installed in the power supply if converting a hand torch system to operate a machine or
automation torch.