TROUBLESHOOTING
6-4 Manual 0-5282
TRANSARC 130i
6.06 Preliminary DC Bus measurement of the main inverter board
WARNING
Check DC bus voltage has discharged to less than 5VDC before servicing. Ensure the mains supply
plug is disconnected from receptacle.
A-11844
DC Bus Testing Multimeter Lead Placement Voltage with Supply voltage OFF
Upper capacitor bank Positive meter lead to testpoint 1
Negative meter lead to testpoint 2
0 VDC
Lower capacitor bank Positive meter lead to testpoint 2
Negative meter lead to testpoint 3
0 VDC
Table 6-2: DC BUS, Multimeter set to measure DC volts