3.15 Fiber Optic Cable Installation
1. Install the through-hole protector for the fiber-optic cable in the hole in connection panel on the back of the
Module.
2. Pass the fiber-optic cable connector through the hole in connection panel on the back of the Module. Pass
enough of the cable into the Module to allow the cable to loop upward as shown.
CAUTION
Avoid kinking, twisting, or bunching the ber optic cable. The cable can be damaged by being forced into tight-
radius turns.
2
3
Circuit Board
Art # A-04772
Fiber Optic Cable
COMM
PLASMA
OUT
PREFLOW
OUT
J57
J56
SHIELD
OUT
H
2
O
INPUTS
TVA
POWER
SUPPLY
H35
F5
AIR N
2
O
2
1
COMM
J57
J56
INPUTS
TVA
POWER
SUPPLY
H35
F5
AIR N
2
O
2
SHIELD
PLASMA
PREFLOW
H
2
O
SHIELD
H
2
O