Owner manual
ULTRA-CUT 100 XT
Manual 0-5272 INSTALLATION 3-5
3.06 Connect Input Power and Ground Cables
Connect Input Power and System Ground Cables
1. Removetheinputpowercovertotherightofthecoolantlterattherearofthepowersupply.Todothis
remove the two screws then lift up and pull away.
2. Carefullycutbacktheoutersheathontheprimaryinputpowercabletoexposetheindividualwires.Cut
backtheinsulationontheindividualwires.RoutethecableupwardthroughInputPowerPortatthebottom
ofthepanel.Thereare2extraplatesincludedatthecableentrance.Discardingoneorbothallowschanging
theopeningsizeforlargercable/strainrelief.
3. Install stripped end of 3 phase wires into the terminal block L1, L2 and L3 and connect the individual cables
as shown.
4. Connectthepowercablegroundwiretothegroundterminalblock.
5. Routeasystemgroundcable(F1)throughthelastopeningintheconnectionscoversupportpanelnextto
the input power cable. Connect the cable to the ground terminal block on the power supply rear panel.
RefertotheGroundConnectionsSectionforfulldetailsandproceduresonpropersystemgrounding.
Input Power
Ground Terminals
Art # A-11970
F1 Ground