Owner manual

ULTRA-CUT 100 XT
Manual 0-5272 INSTALLATION 3-1
SECTION 3: INSTALLATION
3.01 Installation Requirements
Electric Supply
The electrical supply network, the gas and water supply system must meet local safety standards. This conformity
shall be checked by qualified personnel.
Ultra-Cut 100 XT™ Power Supply
Input Power Input Current Suggested Sizes (See Note)
Voltage Freq. 3-Ph 3-Ph Fuse (Amps) Wire (AWG) Wire (mm
2
)
(Volts) (Hz) (kVA) (Amps) 3-Ph 3-Ph 3-Ph
480 50/60 21 26 35-40 #12 4
NOTE
* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the
National Fire Prevention Association. Listings are from table 400.5(A)(2) for exible cord of certain types rated
for 75 deg C in ambient temperatures up to 30 deg C. Using wires of lower temperature rating or dierent insu-
lation type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to your region for nal
determination of correct wire type and size.
Gas Supply
The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure regulators
must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause one or more
of the following problems:
• Reducedcuttingspeed
• Poorcutquality
• Poorcuttingprecision
• Reducedconsumableslife.
• Oilorgreasecontaminationfromcompressedorbottledaircancauseresinconjunctionwithoxygen.
Cooling System Requirements
Coolant must be added to the system on installation. The amount required varies with torch leads length.
Victor Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).
Coolant Capabilities
Cat. Number and Mixture Mixture Protects To
7-3580 ‘Extra-Cool™’ 25 / 75 10° F / -12° C
7-3581 ‘Ultra-Cool™’ 50 / 50 -27° F / -33° C
7-3582 ‘Extreme Cool™’ Concentrate* -76° F / -60° C
* For mixing with D-I Cool™ 7-3583