Owner manual

ULTRA-CUT 100 XT
A-52 APPENDIX Manual 0-5272
104 Transfer Lost
Arc transferred to metal for at least 50 ms. then went out.
Causesfor104code:
• Cutdemandsetmuchlowerthanrecommendedfortorchparts,i.e.100Aconsumablesintorchbutcut
current set for 30 or 50A (or zero). Current may be too low to keep arc on.
• Torchstandofftoohighforcuttingprocessbeingused.
• PlasmagasowtoolowduetoaleaksomewherebetweentheplasmaregulatorortheDPC3000andthe
torch. Check for leaks.
• Remoteanalogcurrentcontrolswitchessetwrong.
o Ifremoteanalogcurrentcontrolisbeingused,SW8-2(CCMCPUPCB)isonandSW11(CCMI/O
PCB)issetto“A”(down)position,butnoanalogvoltageconnectedtoTB1-10orJ15-30(CNCcable)
then cut demand will be zero, pilot will be weak, depending on torch height it may still transfer but
will immediately go out.
o IfremoteanalogcurrentcontrolisnotbeingusedbuteitherSW11issettothedownpositionorSW8-2
is on also results in zero cut demand.
o IfsystemisAuto-CutXT,currentcontrolisananalogvoltagefromtheGCM1000XTortheAC200
XTfrontpanelpot.Thecurrentcontrolsettingwillbeshownonthefrontpanel4digitdisplay.SW8-
2shouldbeoffandSW11settoupposition.Withpotatmax,checkfor3.3VonCCMI/OPCBTP9
(TP1common).WhileturningthepottowardminimumTP9voltageshouldvarylinearlytozeroV.
Art # 12309
2
1
3
SW11
TP9
TP1 GND
0-3.3VDC
GND
Divide
by 3.
From Remote
analog Current
Control
CCM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J26
GND
+10.0V
R1
10K
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J55
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J56
GCM 1000 XT
(125)
(126)
(127)
Auto-Cut XT Power Supply
(AC 300 XT)
R1
10K
AC 200 XT
105 Not Used. This is one of the reserved codes from the earlier product.
106 Pilot Timeout, no Transfer
Pilottimeislimitedtoeither0.085seconds(85ms.)withCCMSW8-1off(defaultforpiercestarting)or3seconds
withSW8-1on(usedforcuttingoverholes,expandedmetal,etc.).Arcmusttransferbeforepilottimeends.
Code106issetifnoarctransfer(currentinworklead)wassensedbeforepilottimedout.Iftheunitdoesnot
detectpilotcurrentthearcstarterwilloperateupto15secondsthensetthe102code.Ifyouaregetting106there
ispilotcurrentsomewhere.Ifit’snotvisibleperhapsit’sinsidetheconsumablesorfollowingsomeotherpart.
Causesfor106code:
No Pilot Visible:
• Pilotinsidetheconsumables
Visible Pilot:
• Firsttheobvious,makesuretheworkleadisconnectedbothtotheworkandthepowersupply.Also
make sure the work itself is making good electrical contact with cutting table. If rusty or painted metal,
you may need to clean a spot and attach the work lead directly to the metal.
• Torchtoofarfromwork.