Status codes.
ThecodesforthepowersupplyaredisplayedontheDisplayPCB4digitnumericaldisplay.Somecodesreferto
theGasControlsbutmoredetailedGasControlcodeswillbefoundontheindividualgascontrols.Thegascon-
trolsusedwiththeXTfamilyofplasmasupplieshavenotchanged.Theyhavetheirownsetofstatuscodeswhich
shouldbecoveredinanothersection.ThisguideassumesyouhaverstconsideredtheStatusCodeTablesinthe
OperationSectionoftheunitmanual.Individualcodeswillpointtodifferentinvertersectionswhilethisguide
groupssimilarcodestogether.ForexamplecodeE(orL)249indicatesaninverterfaultinInverter2A.Thisguide
coverscodes247-252inonesectionastheyareallthesame,varyingonlybywhichinverterandsectiontheyreferto.
Thecodesareseparatedinto6groups.
Group 1 PlasmaProcess--Relatingtopilot,transfer,torchvoltages,etc.
Group 2 PlasmaPowerSupply--PrimarilytheInverterSections
Group 3 Interface to Gas controls -- Mainly the DFC 3000
Group4 CoolingSystem--Theliquidcoolingsystemforthetorchandinverters
Group 5 CCM -- Communications port to the gas controls
FortheXTunitsweareusinga3digitcodewithgroup1codesinthe100’s,group2inthe200setc.Thesecorrespond
totheoldercodesusedinpreviousunits,where1-1isnow101.Forthemostpartthecodeshavethesamemeaning.
WhereanoldercodenolongerappliestotheXTsystemwedon’tuseitoveragainandhaveleftitreservedtoavoid
confusion.Forexamplethecode204(2-4)whichmeanttheinvertermodulewasn’tready.Wenowdetectthaterror
inadifferentwaythathasasomewhatdifferentmeaningsowehavereservedthe204Code.
Whilemostofthecodesindicateafaulthasoccurred,afewofthem,suchas304(formerly3-4),simplyreferto
thecurrentstatus.304indicateseither“priming”wherethepumpisllingthesystemwithcoolantormoreoften
“purging”wherethegasisowingtodrytheconsumablesafterreplacingthemorpurgingthegaslineswhena
different gas type has been selected.
Troubleshooting (General)
In many cases where the cause may be listed as a cable or wire disconnected but also includes loose or broken.
AllRibboncableshaveanextrareceptaclenearoneendformeasuringsignalsonthecable.
A number of the measurements will require probing of some small connectors or measuring signal on ribbon cables.
Forprobingthesmallconnectors,standardmeterprobesareusuallytoobig.Wesuggestmakingacoupleprobes
usingsteelwire.Copperbusswireisn’tstiffenough.Apaperclipisalittletoobig.Oneideaistakeasocketfrom
anAmpmate-n-locorsimilarconnectorintowhichyourmeterprobewilltandcrimpasmallpieceofsteelwire,
(0.020to0.025”dia.;(0.5-0.6mm)worksbest),intowherewirewouldnormallybecrimped.Thewireshouldbe
soldered and crimped. The steel wire may be found in hobby stores that cater to model building.
Art # 12302
Art # 12303
Insulate all but the end of the wire and slide these onto your meter probe. If your meter has alligator clip adaptors
youcouldholdthewireintheseaswell,besuretheydon’tshorttogether.
Problems that do not set Status or Fault codes:
1. AtpoweronGASLEDblinkscontinuously,nocodeset.Realproblemisnoorlowcoolantowbutittakes
4minutesbeforecodeissetandpeopledon’twaitthatlong.