Owner manual
ULTRA-CUT 100 XT
A-42 APPENDIX Manual 0-5272
Appendix 23: Advanced Troubleshooting
System Overview
TheAuto-Cut200&300XT&Ultra-Cut100,200,300&400
XTpowersuppliesincludeone,twoorthreeinvertermod-
ules(IM).EachIMmayhaveeither1or2invertersections
designatedAorBsections.TheIMsaremountedoneover
the other numbered from bottom to top. The sections are
also designated from bottom to top with section A being on
the bottom of each module. An IM with one section is con-
sideredtobea½or“partial”modulewiththeupperor“B”
section missing. ½ modules are used with the 200A & 300A
power supplies and will always be in the middle position.
IMswith2sectionsareconsideredtobe“full”modules.
Eachinvertersectioncansupplyupto67Abutdoesnotdo
soinallcongurations:
A400Aunituses6sections.400A/6=66.67Apersection.
A300Aunituses5sections.300A/5=60Apersection.
A200Aunituses3sections.200/3=66.67Apersection.
A100Aunituses2sections.100/2=50Apersection.
Unit configurations.
WiththeexceptionoftheAC200XTallotherunitshavethe
same chassis with room for up to 3 IMs. The unused areas
haveblankpanelsllingthe emptylocationswhichare
requiredforproperairow.A100Asystemuses1fullIM;
200A uses 1 and ½ modules with a full module in the bottom
location and a ½ module in the middle position. A 300A
unit has full modules top and bottom with the ½ module
in the middle location. The AC 200 XT has only the bottom
and middle locations for IMs. An internal Arc Starter and
Gas Control are located in the place of the 3rd or upper IM.
Inverter module cooling.
Thepowersemiconductorsoftheinvertermodulesareliq-
uid cooled allowing us to get more power in a smaller area
and at lower cost. Each IM has a liquid cooled heatsink or
“coldplate”sharedbythe2invertersections.Themagnetic
components, transformers and inductors, are air cooled and
mounted on the back side of the IMs where they are exposed
tohighvolumesofairowfromthecoolingfanswhoseair
also cools liquid coolant in the radiator or heat exchanger.
It is important that lower right side panel be in place or the
airowwillnotbeproperforcoolingthemagnetics.
Inverter control.
Theinvertersectionsareoperatedas separateinverters
whose outputs are connected in parallel. They are controlled
independently from the Command and Control Module
(CCM)whichisthe“brains”ofthesystem.Eachinverter
section has a separate ribbon cable connected to it coming
fromtheCCMwhichhas6connectors,J31–J36correspond-
ingtotheinvertersections1Athrough3B.Theribboncables
arelabeledontheinverterendsasINVwiththenumberand
Art # 12299
Art # 12300