Owner manual
ULTRA-CUT 100 XT
Manual 0-5272 APPENDIX A-9
Internal CNC connections. TB1, TB2 & TB3 on CCM module.
ConnectionsareprovidedontheCCMmoduleTB1,TB2&TB3terminalblocksincludingmostoftherearpanel
functions plus some additional features. All these signals are isolated from the plasma power supply but signals
marked (comm.) and (-) are common to each other.
UsersareexpectedtoinstalltheirownCNCcabletotheseconnections.Knockoutholeisprovidedinrearpanelof
CCMmodule.Usershallprovidestrainrelief/cordgripforuserinstalledcable.
TB1
Function Connection
CNCEnable/Disable TB1-2(+),TB1-1(-)(comm.)
OKtoMove2 TB1-3&TB1-12Contactsonly,rated1A@28VAC/DC
Stop Latched (NC)
4
TB1-4(+)&TB1-5(-)(comm.)usedwithStartLatched
Start/StopRet
4
TB1-6(+),TB1-5(-)(comm.)
or Start Latched (NO)
4
TB1-6(+),TB1-5(-)(comm.)usedwithStopLatched
DividedArcVoltage TB1-8(+),TB1-7(-)comm.
RemoteAnalogCurrentControl TB1-9AnalogComm.(-)or10KCCPotlow
TB1-10Analogin(+)orCCPotWiper
TB1-1110KCCPotHi(+10V@1ma.Supply)
TB2
Function Connection
HoldStart TB2-2(+),TB2-1(-)(comm.)
PreowON TB2-4(+),TB2-3(-)(comm.)
PilotisON(contacts) TB2-6,TB2-8rated1A@120VACor28VDC
OKtoMove(contactsorDCVolts) TB2-12(+),TB2-10(-)
TB3
Function Connection
PlasmaMarking TB3-2(+),TB3-1(-)(comm.)
CornerCurrentReduction TB-4(+),TB3-3(-)(comm.)
CutExpandedMetal TB3-6(+),TB3-5(-)(comm.)
Spare NO Contact TB3-7, TB3-8
Spare NC Contact TB3-9, TB3-10
Spare NO Contact TB3-11, TB3-12