Owner manual

ULTRA-CUT 100 XT
7-4 TORCH INFORMATION Manual 0-5272
CAUTION
The cartridge assembly must cover the O-Ring on the torch head.
Do not force the cartridge if it will not tighten fully. Remove the cartridge assembly and gently clean the threads
on the torch head with a wire brush. Apply oxygen-compatible lubricant (supplied with the torch) to the threads.
To rch Head O-Ring
Torch Head
Art # A-07202
0.063 - 0.083"
(1.6 - 2.1 mm)
Protrusion
Installing Assembled Cartridge Onto Torch Head
3. Slidetheohmicclipovertheshieldcupifusingohmictorchheightcontrolsensing.
NOTE
Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Ohmic Clip
Art # A-03393_AB
4. Connectthewireleadfromtheheightndertotheohmicclip.