4-26 OPERATION Manual 0-5303
Group 5 - Shorted Solenoid Faults
5-1 Sol 1 – H35 Plasma Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-2 Sol 2 – Oxygen Plasma Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-3 Sol 3 – Air Plasma Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-4 Sol 4 – Nitrogen Plasma Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-5 Sol 5 – Aux Plasma Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-6 Sol 6 – Oxygen Shield Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-7 Sol 7 – Air Shield Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-8 Sol 8 – Nitrogen Shield Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-9 Sol 9 – H2O Shield Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-10 Sol10–OxygenPreow Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-11 Sol11–AirPreow Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-12 Sol12–NitrogenPreow Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-13 Sol 13 – Argon Marking Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-14 Sol 14 – Air Marking Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
5-15 Sol 15 – Nitrogen Mark-
ing
Replacesolenoid;Shortedwireharness;DefectiveDMCControlPCB
* Communication faults shown on the DMC can be caused by the device on the other end of the communication line.
Before assuming the DMC is at fault see if either the CCM or the DPC are showing any codes that might indicate they are at
fault instead.
4.13 DPC-3000 Status Codes
DPC Status Code Key
Group 1 - DPC
Code Message Cause/Remedy
1-1 Plasma Disabled EnablePlasma;DMCPowerSupplyinputfuseF1blown(nolightsonDMC);DefectiveDMC
Power Supply (E-Stop relay). Defective DPC Power Supply (E-Stop relay). Defective DPC control
PCB
1-2 24 VDC fault Check/replaceDPCpowersupplyoutputfuse(F2);DefectiveDPCpowersupply;ReplaceDPC
control PCB
1-3 +12 VDC fault Check/replaceDPCpowersupply;ReplaceDPCcontrolPCB
1-4 -12 VDC fault Check/replaceDPCpowersupply;ReplaceDPCcontrolPCB
1-5 5 VDC fault Check/replaceDPCpowersupply;ReplaceDPCcontrolPCB
1-6 Analog Reference fault Replace DPC Control PCB
1-7 ADC voltage fault Replace DPC Control PCB
1-8 Reserved
1-9 Valve not configured Resend process from TSC 3000 / CNC
1-10 DPC is locked Process loading, wait until finished
Group 2 - Control Communication
2-1 Acknowledge error Fiberopticcable;DPCControlPCB
2-2 Timeout Communicationloss:CheckDMCcodes;ifDMC2-1checkDPCtoDMCFiberopticcable,DMC
4-2checkDMCtoCCMber-opticcable.;DPCControlPCB;DMCControlPCB;CCM.
2-3 Protocol Program firmware fault, consult factory
2-4 Bus off Fiberopticcable;DPCControlPCB
2-5 Physical Fiberopticcable;DPCControlPCB