Manual

ULTRA-CUT 100 XT
4-22 OPERATION Manual 0-5303
CCM Status Code
Group 3 -- Gas Controller Status & Protocol
Code Message Remedy / Comments
301
Gas control communication
fault
ProblemwithberopticcabletoGCM2010orDMCorDPC;Dirtonberends
orinconnectors;blowoutwithcleandryair.Fibernotlockedintoconnector;
Sharpbendsinbercable;Fiberdefective;GCM2010circuitboarddefect;
DMCorDPCpowersupplydefective;DMCorDPCcircuitboarddefect
302 Gas Control reply fault
ProblemwithberopticcabletoGCM2010orDMCorDPC;Dirtonberends
orinconnectors;blowoutwithcleandryair.Fibernotlockedintoconnector;
Sharpbendsinbercable;Fiberdefective;GCM2010circuitboarddefect;
DMCorDPCpowersupplydefective;DMCorDPCcircuitboarddefect
303
Gas Supply Pressure out of
range.
GCM 2010 inlet plasma or shield pressure low or defective pressure sensors
PS3&PS4;DefectiveGCM2010PCB;ForDFC3000seeDPCforpressure
faults.
304 Gas Control Purging
Normal following power up or returning from Plasma Disable. Wait for purge
to finish.
305 Gas Control protocol error
Verify Firmware revision for compatibility with GCM 2010 or DMC and DPC
306 Not used Reserved for other future use.
307
Gas Control sequencing
error Verify Firmware revision for compatibility with GCM 2010 or DMC and DPC
308 Gas Control Type Mismatch WrongCCM(Auto-CutorPak200type?)forUltra-Cut;InstallcorrectCCM
309 Gas Control command fault
VerifyFirmwarerevisionforcompatibilitywithGCM2010orDMCandDPC;
ElectromagneticinterferencewithArcStarter;inspectgrounding;bonding;and
isolation
310 * DPC fault
Check DPC status indicator for specific problem
311 * DPC valve controlling fault
Check DPC status indicator for specific problem
312 * DMC fault
Check DMC status indicator for specific problem
313 *
Gas Controller not config-
ured. DMCorDPCnotconguredforaprocessorlocked;SeeDMCandDPCstatus
* Applies to DFC 3000 (Auto Gas) only