Manual 0-5303 OPERATION 4-17
4.11 CCM Status Codes
NOTE
See the Appendix for Advanced Troubleshooting
On start-up and during operation, the power supply control circuitry performs various tests. If the circuitry detects
a condition requiring operator attention, the status display on the front panel shows a 3 digit number code preceded
by either letter “E” (currently active fault) or letter “L” (last or latched fault) meaning a fault occurred during the
process but is not currently active.
Some conditions can be active indefinitely, while others are momentary. The power supply latches momentary
conditions; some momentary conditions can shut down the system. The indicator may show multiple conditions
in sequence; it is important to recognize all possible conditions that may be displayed.
NOTE
There are no Group 5 (500) numbered status codes with the GCM 2010 system. These tables cover units
up to 400A, Lower current units won’t have all the inverter sections referred to in the Group 2. However
codes for those sections should not appear.
CCM Status Code
Group 1 -- Plasma Process
Code
Message
Remedy / Comments
101 Plasma Disabled
PlasmaEnableOff;DisableactivatedonTSC3000orGCM2010orexternal
SWdisabled(CNC);CCMTB1-1&2jumpermissing;40circuitribboncable
fromRelayPCBtoCCMdisconnectedordefective;
102 Pilot Ignition Failure
Pilot did not start within 15 seconds. Torch consumable parts worn? Ensure
correct process selected or manual setting including current control setting
matchesconsumables;Plasmapressuretoohigh;DefectiveArcStarter;
DefectivePilotPCB;defectiveInvertersection1A.Ribboncablesreversedon
INV1 sections 1A and 1B.
103 Lost Pilot
Pilot went out while Start active. Torch consumable parts worn? Ensure cut
processorcurrentcontrolsettingsettingmatchesconsumables;Plasma
pressuretoohigh;
104 Transfer Lost
Arc was transferred to work then went out while Start still active. Arc lost
contactwithwork(runoffedge,overhole,etc.);Standofftoohigh;Ensure
cut process or manual settings (current control, gas pressures) matches
consumables;
105 Not used Reserved for legacy product
106 Pilot Timeout, no Transfer
Must transfer from Pilot to Cutting Arc in 0.085 seconds (SW8-1 OFF) or 3
sec.(SW8-1ON).Standofftoohighorvoidinworkundertorch;Wrongcut
process selected or wrong manual settings (current control set too low or
wrong gas pressure).
107 Not used Reserved for legacy product
108 Tip to Electrode voltage fault.
Tipvoltagetooclosetoelectrodevoltage;Torchconsumablepartswornout;
Wrongconsumablesinstalledcausingtiptoelectrodeshort;Wrongprocess
selectedorwrongmanualsettingofplasmagasorcuttingcurrent.;Leakin
Plasmahosetotorch;DefectivePilotPCB;Shortedtorchbody.
109 Part process not configured.
Applies only to DFC 3000 Auto Gas Control. Select and load a cutting pro-
cess.
110 Not used Reserved for legacy product