Manual

ULTRA-CUT 100 XT
3-36 INSTALLATION Manual 0-5303
Output Connections
1. Refer to the illustrations. Make the following output connections to the Arc Starter.
Pilot Lead
Art # A-12065
Green
Red
Coolant Return (Red)
Coolant Supply (Green)
Pilot Return Cable, CoolantSupplyandReturnHoses(fromTorch)
2. Reinstall the Arc Starter Cover. Ensure that the ground wire is not crimped between the cover and the base.
Art # A-12059
Lower screws
(2 per side)
Upper screws (2 per side)
Cover
Ground Wire