A-64 APPENDIX Manual 0-5303
238 System Bias voltage identification is invalid.
At power up the System Bias board measures the input voltage and sends signals to the CCM indicating which
range of voltage it has detected. See section 231-236 for details. If one of the 3 voltage ranges, 208-230V, 380-
415V or 480V isn’t identified then both ID signals are high resulting in an invalid signal.
Possible causes:
• Unitisconnectedtovoltagebelowthe208-230Vrangeorabovethe480Vrange.(unlikelyunlessthereis
a problem with the incoming voltage.)
• DefectiveSystemBiasboard
• BadconnectionbetweenSystemBiasoutputJ62andCCMinputJ27ontheI/Oboard.
• DefectiveCCM
Troubleshooting:
1. Measure all 3 phases of the input voltage and conrm they are within the tolerance specied in the unit
manual.
2. Refer to section 231-236 Inverter VAC Mismatch and perform troubleshooting in step 1.b. If the 2 signals
don’t match the incoming voltage, if both are high, then the System Bias is defective.
3. If step 2 was OK make the same measurement at J27 on the CCM I/O PCB. If OK here the CCM is defec-
tive. Otherwise inspect the connections at J62 and J27.
239 AC Voltage High
Voltage OK -- At power up the System Bias board measures the input voltage and determined if it is within the
range of voltage set by the J16 jumper. See section 231-236 Inverter VAC Mismatch Troubleshooting step 1.a
for details of the jumper. Normally when the input voltage is OK the System Bias board turns on a relay K1
on the left die of the board to apply power to the T1 Auxiliary transformer. D44, a green “Transformer ON”
LED, will light when K1 is energized. T1 provides power to the gas controls and the TSC 3000 as well as the
pumps and fans.
Voltage High -- If the AC voltage is determined to be too high it lights D4, ACV HIGH, a red LED on the System
Bias board, and sets the signal “AC V HIGH b” on J62-6 to a “high” about 24VDC (normal for a “low” here is
10-14VDC). To prevent the possibility of excessive voltage applied to several items (gas controls, pumps, fans
etc.) K1 is opened removing power from T1 and D44 goes off. If it’s more than a momentary glitch the gas
controls and the TSC 3000 (if used) will reset. Communication with the cutting table may be interrupted. With
the DFC 3000 Auto Gas Control and perhaps the cutting table control, the process will have to be reloaded.
D4 is on and the signal “AC V HIGH b” is high only while the voltage is actually high. The signal “AC V HIGH
b” does not latch on.
If the fault is E239 that means it is currently active, that is, currently detected as being too high. If it’s L239 that
means the voltage too high previously but it is not too high now. Applying START will clear the fault unless
it becomes active again.
The voltage that triggers an AC Voltage High fault is above 550V for 480VAC line; above 470V for a 380, 400 or
415V nominal line; above 270V for a 208 or 230VAC line.
Possible causes:
• Incomingvoltageisorwastoohigh.
• BadconnectionatJ62orJ27
• BadconnectionatJ61jumper
• SystemBiasboarddefective
• CCMdefective.