104 Transfer Lost
Arc transferred to metal for at least 50 ms. then went out.
Causes for 104 code:
• Cutdemandsetmuchlowerthanrecommendedfortorchparts,i.e.100Aconsumablesintorchbutcut
current set for 30 or 50A (or zero). Current may be too low to keep arc on.
• Torchstandofftoohighforcuttingprocessbeingused.
• PlasmagasowtoolowduetoaleaksomewherebetweentheplasmaregulatorortheDPC3000andthe
torch. Check for leaks.
• Remoteanalogcurrentcontrolswitchessetwrong.
o If remote analog current control is being used, SW8-2 (CCM CPU PCB) is on and SW11 (CCM I/O
PCB) is set to “A” (down) position, but no analog voltage connected to TB1-10 or J15-30 (CNC cable)
then cut demand will be zero, pilot will be weak, depending on torch height it may still transfer but
will immediately go out.
o If remote analog current control is not being used but either SW11 is set to the down position or SW8-2
is on also results in zero cut demand.
o If system is Auto-Cut XT, current control is an analog voltage from the GCM 1000 XT or the AC 200
XT front panel pot. The current control setting will be shown on the front panel 4 digit display. SW8-
2 should be off and SW11 set to up position. With pot at max, check for 3.3V on CCM I/O PCB TP9
(TP1 common). While turning the pot toward minimum TP9 voltage should vary linearly to zero V.
Art # 12309
2
1
3
SW11
TP9
TP1 GND
0-3.3VDC
GND
Divide
by 3.
From Remote
analog Current
Control
CCM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J26
GND
+10.0V
R1
10K
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J55
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J56
GCM 1000 XT
(125)
(126)
(127)
Auto-Cut XT Power Supply
(AC 300 XT)
R1
10K
AC 200 XT
105 Not Used. This is one of the reserved codes from the earlier product.
106 Pilot Timeout, no Transfer
Pilot time is limited to either 0.085 seconds (85 ms.) with CCM SW8-1 off (default for pierce starting) or 3 seconds
with SW8-1 on (used for cutting over holes, expanded metal, etc.). Arc must transfer before pilot time ends.
Code 106 is set if no arc transfer (current in work lead) was sensed before pilot timed out. If the unit does not
detect pilot current the arc starter will operate up to 15 seconds then set the 102 code. If you are getting 106 there
is pilot current somewhere. If it’s not visible perhaps it’s inside the consumables or following some other part.
Causes for 106 code:
No Pilot Visible:
• Pilotinsidetheconsumables
Visible Pilot:
• Firsttheobvious,makesuretheworkleadisconnectedbothtotheworkandthepowersupply.Also
make sure the work itself is making good electrical contact with cutting table. If rusty or painted metal,
you may need to clean a spot and attach the work lead directly to the metal.
• Torchtoofarfromwork.