User Manual

18 Multi Format LCD Monitor Multi Format LCD Monitor 19
<Dynamic UMD Protocol (TSL V3.1)>
*
Transmission (18 Byte) (PC or Device -> Monitor)
*
[HEADER] : Display address (0~126) + 80 hex.
*
[CONTROL BYTE]
bit 0 : Tally 1 (1=on, 0=o)
bit 1 : Tally 2 (1=on, 0=o)
bit 2 : Tally 3 (1=on, 0=o)
bit 3 : Tally 4 (1=on, 0=o)
bit 4 : bright data (Not used)
bit 5 : bright data (Not used)
bit 6 : reserved (Not used)
bit 7 : cleared to 0 (Not used)
*
[DISPLAY DATA] : 16 displayable ASCII characters.
HEADER
(1 BYTE)
CONTROL
BYTE(1 BYTE)
DISPLAY DATA
(16 BYTE)
Tally1
C H A N N EL1
Tally2 Tally3
C H A N N EL1
Tally4
[4] GPI / UMD [4] GPI / UMD
Bit 1
(Tally2)
Bit 1
(Tally1)
Operation
0 0
C H A N N EL1
0 1
C H A N N EL1
1 0
C H A N N EL1
1 1
C H A N N EL1
Bit 1
(Tally4)
Bit 1
(Tally3)
Operation
0 0
C H A N N EL1
0 1
C H A N N EL1
1 0
C H A N N EL1
1 1
C H A N N EL1
The following appearance of UMD DISPLAY is set as D-UMD(D-8C), D-UMD TALLY TYPE
and TALLY1 ~ TALLY4 COLOR.
D - U M D TA L LY T Y P E
TA L LY1 CO L O R
TA L LY 2 CO L O R
TA L LY 3 CO L O R
TALLY4 COLOR
USER COLOR
RED
GREEN
RED
YELLOW
C H A N N E L1 C H A N N E L1
Tally Type - Default
- S-8C(Single 8 Character) & S-16C(Single 16 Character)
D-UMD TALLY TPYE - USER COLOR
- Color selections between TALLY1 ~ TALLY4.
- D-8C(Dual 8 Character)
5. Menu Operations 5. Menu Operations