User's Manual

FHD Viewnder Monitor 36
7. Other Functions
[14] Firmware Upgrade [13] ARRI Camera Status
• The USB(Thumb drive) which contains the
F/W le is needed for Firmware Upgrade.
• Select the SW UPGRADE in the SYSTEM
menu.
1. Connect the USB to the USB Slot on the
front of the monitor.
2. Select what to update among CPU / FPGA
/ ALL in [S/W UPGRADE].
3. When the USB connection is completed,
the S/W upgrade starts and the progress
displays on the bottom left side of the
screen.
4. If the USB doesn’t connect properly or
there is no  le in the speci ed location,
the error message will be displayed on
the bottom left side of the screen and the
upgrade won’t start.
5. In that case, check the USB or the  le
location and try again.
• After USB connection, turn o and then on
the monitor.
• Used to display the camera status
information provided by ARRI ALEXA
camera on the OSD.
- Displays the information in the order: [Project
FPS]-[Exposure Time]-[White Balance]-[White
Balance CC]-[Camera Index Letter] / [Lens
Name]-[Focal Length]-[Iris]-[Focus Distance] /
[Lens Squeeze Factor]-[Scene]
- When the Arri Cam Status is activated, the
screen will be scaled to 1742 x 980.