Installation Guide
CB66 - CB67 - CB68 Operator's manual 7
GB
2.1 Temporary disabling of the diameter and distance sensor
(where applicable)
If the machine displays the error code Err 016 “dis out” (distance/diameter sensor not in the rest
position) at start-up, although being in rest position, it means that an anomaly has occurred in the acqui-
sition system.
It is however possible to immediately (and temporarily) disable the acquisition system by pressing the button
[F + P2]
. The LED [6], located on the control panel, will light up to indicate that
the automatic acquisition system is disabled and that the machine is ready for use.
Not being able to use the automatic acquisition system, sizes of the wheel must be entered manually as
described in chapters 3.3.1 and 3.3.2. By switching the machine off and then on, the error code will be
displayed again for which it will be necessary to repeat the procedure described above.
3. USE OF THE MACHINE
To use the machine, you must select or set as follows:
• Programme type (programme for wheels with steel, aluminium or special aluminium rims).
Default = programme for wheels with steel rims;
• Wheel Type (auto-vehicle, motorbike, off-road). Default = auto-vehicle;
• Dimensions of the wheel to balance. The dimensions can be entered manually (always) or partially or fully
in automatic (only available on some models).
• Dynamic or Static balancing. Default = Dynamic;
• Display resolution X1 or X5. Default = X5;
The selections described above may be entered before or after the launch. For any variation of the selection
or data settings, the machine will run a recalculation by displaying the new values of imbalance.
Once the selections/settings have been entered, you can run a launch by pressing [P8] Start
or by
lowering the wheel guard.
At the end of the launch, the machine displays the wheel imbalance values.
Apply the weights displayed by the machine at the indicated positions and then run a second test launch.
Normally, the weights should be applied at the 12 o’clock position with the exception of special programmes
for ALS2 and ALS1 aluminium.