Installation Guide

42 CB66 - CB67 - CB68 Operators manual
option is viewed, then press [F+P9] to con rm the selection.
Note:
the test programmes listed are mainly reserved for technical support personnel but may also be run by end users
as it does not impair machine operation.
9.14.1 EnC Encoder disc test
This test allows controlling the function of the encoder which informs the machine on the angular position
of the shaft. A number indicating the angular position will appear on the right display; this number must
be between 0 and 255.
To exit the test programme, press [F+P9]
.
9.14.2 rPM number of shaft RPMs test
This test allows controlling the number of shaft RPMs during the launch. A number indicating the speed
of the shaft will be viewed on the right display.
By pressing [P8] Start
the machine will run a launch and at the end of this, it will display the number
of shaft RPMs.
To exit the test programme, press [F+P9]
.
9.14.3 SIG Pick-up signals test;
This programme allows checking the pick-up signal. To run the test, you will need to mount a balanced
wheel with steel rim, 15” in diameter and 6” in width (or more similar as possible), on the machine. A 50 g
weight must be applied the external side of the wheel.
By pressing [P8] Start
, the machine will run continuous spinning and the pick-up signals respect to
the three attenuation processes (Attenuation 1, Attenuation 2, Attenuation 4) will appear on the display
in sequence.
To complete the test, press [P10] Stop
or raise the wheel guard.
To exit the test programme, press [F+P9]
.
9.14.4 dPy Display test
The display test program will light up all the LEDs and the 7-segment displays in sequence so you can
check their functioning. To turn on all the LEDs and display segments in sequence, press [P4]
or [P5]
.