Installation Guide
CB66 - CB67 - CB68 Operator's manual 35
GB
8. UTILITY PROGRAMMES
Utility programmes are available only in NORMAL mode.
8.1 Selecting the imbalance display resolution
The machine has two wheel imbalance display resolutions. The two resolutions are defi ned as X1 (high
resolution) and X5 (low resolution).
The resolution with which the imbalances of the wheel are displayed varies depending on the unit of weight
as indicated in table T8.1.
Table T8.1 Display resolution
Set resolution Imbalance unit of measure Display resolution Notes
X1
(high resolution)
Grams 1 gram
Ounces 0.1 ounces
X5
(low resolution)
Grams 5 grams
The X5 resolution is set by
default at start-up
Ounces 0.25 ounces
To view the imbalance in X1 resolution (high resolution) press [F+P1]
. The machine will
display the message visible in Figure F8.1.0a for one second and the LED next to the button will turn on.
Imbalance values are now displayed in X1 resolution (high resolution).
Fig. F8.0a Enabling of the imbalance display in high resolution.
To return to viewing in X5 resolution (low resolution) press [F+P1]
again. The machine
will display the message visible in Figure F8.0b for one second and the LED next to the button will turn off.
Imbalance values are now displayed in X5 resolution (low resolution).
Fig. F8.0b Disabling imbalance view in high resolution.