Installation Guide

CB66 - CB67 - CB68 Operator's manual 33
GB
Fig. F6.4 Input of the weight W2 position
7. Rotate the wheel manually until the point where you want to apply the external weight W2 is reached
and press [P1]
y
to con rm. The angle formed by the weights W1 and W2 must not be less
than 120° and must include the external weight W.
8. If the chosen angle is greater than 120°, the machine will display Fig. F6.2 for one second and will emit
a triple beep meaning to repeat the procedure in step 7 again. If the angle instead is less than 120°,
the machine will immediately display the value of the external weight W2.
9. Block the wheel and apply the external balancing weight W2 as indicated on the display. Consult table
T3.1.1 for the exact application point of the external weight.
10. Manually rotate the wheel until external weight value W1 does not appear on the left display.
11. Block the wheel and apply the external balancing weight W1 as indicated on the display. Consult table
T3.1.1 for the exact application point of the external weight.
12. The Hidden Weights programme procedure is completed: press [F+P5]
to exit and
run a balancing test launch.
Note:
gure F6.1 indicates the position of the external weight at the 12 o’clock position but this is valid only for certain
Programme Types. Table T3.1.1 shows the actual position of the external imbalance based on the Programme
Type and on the enabling state of the Distance/Diameter sensor.
7. SECOND OPERATOR
The machine has two separate memories allowing two operators to work simultaneously with different
settings.
This feature can make operations at the workshop quicker because when, for example, an operator is
busy with removing or remounting a tyre, the other operator can use the machine to perform balancing
operations and vice versa.
In this manual, the two operators are de ned as operator 1 and operator 2.
When operator 1 has completed his tasks on the machine or is involved in other activities, operator 2 can
work with the machine using the settings for the wheel type he is working on without altering the settings
entered by operator 1.
When the machine is switched on, the two memories are set with the same values by default.
To use this function, operator 2 must proceed as follows:
1. When the machine is free, press [F+P6]
to select operator 2. The LED located next
to the button lights on to indicate that operator 2 is enabled. The message shown in gure F7.1 will
be displayed for one second.