Installation Guide
CB66 - CB67 - CB68 Operator's manual 31
GB
b) Press [F+P4] to exit the optimisation programme and to directly return to the
operating programme;
Fig. F5.7 “Final valve alignment with the mark on the tyre” message
8. Rotate the wheel until all position arrow LEDs light up and then mark the 12 o’clock position as shown
in fi gure F5.4;
9. Remove the wheel from the balancing machine, remove the bead from the tyre and rotate it until the
valve matches the mark on the tyre;
10. Optimisation is completed: exit the optimisation menu by pressing [F+P4]
.
11. Remount the wheel on the balancing machine and balance it with the normal procedure.
6. HIDDEN WEIGHTS PROGRAMME
This programme divides the external weight W in two weights W1 and W2 (smaller than the initial external
weight W) located in any two positions selected by the operator.
The two weights W1 and W2 must form a maximum angle of 120° including the external weight W, as
shown in Figure F6.1.
VALID
The angle between weights
W1 and W2 is < 120° and
includes the initial external
weight W.
NOT VALID!
The angle between the
weights W1 and W2 is ≥ 120°
NOT VALID!
External imbalance W not
between W1 and W2
Fig. F6.1 - Hidden Weights Programme: valid and invalid conditions for use
The Hidden Weights programme is used for aluminium rims when:
• you want to hide the external weight behind two spokes for aesthetic reasons;
• the position of the external weight coincides with a spoke therefore a single weight cannot be applied.