16. ... Calibration is completed: the machine automatically exits the calibration programme and returns to
the NORMAL mode, ready to perform the balancing.
If during machine calibration there are some anomalies, error codes will be displayed (e.g. Err 025). See
chapter 6.1 Error Codes and act accordingly to eliminate the problem and to continue/repeat/cancel the
calibration in progress.
The launches interrupted by pressing [P10] Stop
or by raising the wheel guard may be repeated
by pressing [P8] Start
y
p
or by lowering the wheel guard.
4.2.1 How to exit the CAR/SUV Wheel Type calibration
You can exit the ongoing calibration procedure at any time by pressing [F + P3] . The
machine will return to the SERVICE mode displaying the writing SER SER. To return to the NORMALE mode,
press [F+P3]
again.
The calibration procedure in progress will be cancelled and the balancing results will use previous calibration
values.
4.3 Calibration according to the MOTO Wheel Type
Calibration for the MOTO Wheel Type (wheels for motorbikes) is completely separated from the machine
calibration for the CAR/SUV Wheel Type because it takes into account the fact that the machine uses a
special ange for motorcycle wheels that slightly alters the balancing of the shaft.
If MOTO Wheel Type calibration has not been carried out and you try to run a balancing launch when the
MOTO Wheel Type is selected, the machine will not run the launch and will display the error code
ERR
031
.
To calibrate motorbike wheels, proceed as follows:
1. Switch the machine on;
2. Apply the ange on the shaft for motorbike wheels as shown in Figure F4.1.
CAL
CAL
Fig. F4.1 Application of the motorbike ange onto the shaft. Align the writing “Cal” on the ange
and on the ange for motorbikes