Product Manual
3
INSTALLATION INSTRUCTIONS
Choosing A Location
•
Use architects' plans when available. See Floor Layout on Page 6 for typical layout
of the12000# inverted cylinder model.
•
Two Post Lifts require a minimum ceiling height of 3” higher than the overall height
of the lift being installed. For the TP12KC-D this will be 168” (14').
• The Steel Reinforced Concrete floor must be level, have a minimum thickness of 4
inches, and retain a commercial rating of 3500 psi. The concrete must
be cured for a
minimum of 28 days.
• Before making a Final Decision, consider the amount of workday traffic flowing in
and around the location you have chosen. Also consider the amount of room out front
of the lift for a workbench or diagnostic equipment. There may also be some future
building plans to consider. Are you satisfied with your selection?