Product Manual
14
ALL ANCHOR BOLTS SHOULD ALWAYS BE TIGHT. Check the bolts periodically
and tighten if necessary to 60-90 ft.-lbs. after the bolts have been set at installation. If any
of the bolts do not function for any reason, the lift should be shut down until the bolt has
been replaced.
EVERY SIX (6) MONTHS:
1. Make a visual inspection of all moving parts for possible wear, interference or damage.
2. Check all pulleys for proper lubrication. If pulleys seem to be dragging during lifting
or lowering, lightly oil the axle.
3. Check and adjust as necessary, equalize tension to insure level lifting.
4. Check columns for plumbness.
5. Check fluid level of power unit.
6. Lube columns.