Product Manual

10
MSC-6KLP
Aug 2017
STEP 8
Assemble the main side arm restraints for column side & swing arms to lifting frame. (Figs 26 & 27)
Fig. 26 Fig. 27
STEP 9
Attach latch release cable bracket to carriage (Fig. 28). Ensure latch release cable is routed thru hole
in bracket.
Fig. 28
STEP 10
Remove the plastic fill cap from the topside of the reservoir and fill the reservoir with approx. 12
quarts of Non-Detergent / Non-Foaming Hydraulic Oil - SAE-10, AW 32 or equivalent. Add hydraulic
oil to the fill line on the front side of reservoir tank.
STEP 11
Connect the power unit’s cord with plug w/ grounding pin to electrical 110-115VAC power source. If
an extension cord is required, ensure the proper gauge extension cord is used. If there is any
question on the power source requirements, please consult an electrician.
The MSC-6KLP Lift is now ready for Operation.
(See Operation Instructions in following Pages)