5.5 OTHER MESSAGES
MESSAGE EXPLAINATION
1 Configuration error a. Missing one or more columns.
b. Columns are not in pairs.
c. Add one pair of column not in RESET state.
2 PLC comm. error:
L2
Communicating of column 2# failed in self- checking
or running:
a. Column 2# is without power or in error
b. Address of column 2# is not correct.
3 Encoder comm.
error: L2
Encoder of column 2# does not communicate with
main PLC
a. Encoder of column 2# is not working
b. Address of encoder of column 2# is not
correct.
4 Stop! a. One emergency button is pressed.
b. Communication between columns is broken.
c. One or more column is power off.
d. Within 2 second after button is released.
5 Arrive at travel end One column stops after reaching its height limit.
(this column will not raise when lower down)
6 Voltage deficient
After moving stopped, one or more columns were
found battery in low voltage. The lift will not raise up
any more but may lower down.
7 Reset! RESET state. Lift is back in ZERO bias.
Free movement is possible and pair of column can be
added or taken away.
Any operation will leave this REST state.
8 Free move,
max. 5s/ step
Under RESET status, when single wheel operation is
chosen. In FREE MOVEMENT, max. 5 sec. in single
pressing can be carried out.
9 Too light & too
slowly!
Because of light loading, lowering speed is below
10mm/s.
10 Accelerating… System accelerates the lowering speed automatically
in order to reach the floor within 4 minutes.