Installation Guide
15 
MR6.5K-38 
Feb 2020 
Inspection, Maintenance & Cleaning 
Always unplug the Power Cord from the electrical outlet before performing any 
inspection, adjustments, maintenance and/or cleaning. 
BEFORE EACH USE: Inspect the general condition of the Lift. Check for loose screws, misalignment 
or binding of moving parts, broken parts, damaged electrical wiring and hoses, and any other condition 
that may affect its safe operation. If abnormal noise or vibration occurs, have the problem identified and 
corrected before further use. Do not use a damaged equipment. 
DAILY: With compressed air or vacuum, remove all dirt and debris from the Lift. Also, use a detergent 
or mild solvent to remove oil and grease from the unit. Then, use a premium quality, machine oil to 
lubricate all moving parts. 
MONTHLY: With the lift fully lowered, check the level of hydraulic oil in the Reservoir Tank is close to 
the Max Fill Line. If not, remove the Fill Cap and add premium quality hydraulic oil until the level of oil 
is even with the Max Fill Line. After filling, place the Fill Cap to Reservoir Tank. 
Never Add Hydraulic Fluid while Lift is in raised position!! 