Inspection, Maintenance & Cleaning
Always unplug the Power Cord from the electrical outlet before performing any
inspection, adjustments, maintenance and/or cleaning.
BEFORE EACH USE: Inspect the general condition of the Lift. Check for loose screws, misalignment
or binding of moving parts, broken parts, damaged electrical wiring and hoses, and any other condition
that may affect its safe operation. If abnormal noise or vibration occurs, have the problem identified and
corrected before further use. Do not use a damaged equipment.
DAILY: With compressed air or vacuum, remove all dirt and debris from the Lift. Also, use a detergent
or mild solvent to remove oil and grease from the unit. Then, use a premium quality, machine oil to
lubricate all moving parts.
MONTHLY: With the lift fully lowered, check the level of hydraulic oil in the Reservoir Tank is close to
the Max Fill Line. If not, remove the Fill Cap and add premium quality hydraulic oil until the level of oil
is even with the Max Fill Line. After filling, place the Fill Cap to Reservoir Tank.
Never Add Hydraulic Fluid while Lift is in raised position!!