U S E & C A R E Waterwise 7000 G U I D E ™ Water Distiller See important safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. A lightning bolt within an equilateral triangle is intended to alert user to risk of injury from electric shock.
IMPORTANT SAFEGUARDS A person who has not read and understood all operating and safety instructions is not qualified to operate this appliance. When using this appliance, always adhere to basic safety precautions including: READ ALL INSTRUCTIONS BEFORE USE. FOR COMMERCIAL AND HOUSEHOLD USE. 1. Operate indoors on a dry, level, well-supported, stable surface. DO NOT use outdoors. DO NOT operate in a moving vehicle. 2. DO NOT allow children to be near Distiller without close supervision.
Electric Cord Statement CAUTION: Your Distiller has a short cord as a safety precaution to prevent injury or property damage resulting from pulling, tripping or becoming entangled with the cord. Do not allow children to be near this Distiller without close adult supervision. If you must use an extension cord with this Distiller, the cord must be arranged so that it will not drape or hang over the edge of a countertop or tabletop where it can be pulled on by children or tripped over.
UNPACKING • The Waterwise 7000 is packaged to prevent damage in shipping. If any damage is found, immediately notify the carrier who made delivery and/or the company from which it was purchased. After opening box and removing Distiller, lift hinged cover to boiler tank area and remove ALL packing material. NOTE: Each Distiller is individually tested to ensure high quality standards. Water residue (deposits) may be evident in the boiler tank as a result of this quality control procedure.
Reservoir Assembly 8 Gallon Model Reservoir Assembly 12 Gallon Model 1. To install plastic feet, place reservoir on the floor, open side down, so legs are pointing up. 2. Install a plastic foot on bottom of each leg. Turn reservoir over so that it stands open side up (fig. C). 3. Decide if you wish to mount sight gauge faucet on either the wide or narrow side of the reservoir. Install sight gauge faucet by placing one rubber washer (flat side against outside of reservoir) onto threaded end of the faucet.
NOTE: If installing a Remote Faucet Pump System, please refer to Remote Faucet Pump System Use and Care Guide in order to complete reservoir assembly. to have an unwanted taste or odor. Order replacement filters from the outlet where you purchased your Distiller. NOTE: This Distiller meets the listing requirements of Underwriters Laboratories Inc. but they have not investigated the physiological effect of the use of these carbon filters, beneficial or otherwise. 6.
WATER SUPPLY CONNECTION Reinstall Boiler Tank CAUTION: To avoid personal injury or property damage, be certain Distiller is unplugged before installing boiler. Installation NOTE: All state, provincial and local laws and regulations must be followed in the installation and use of your distiller. 1. Place hook of the boiler tank over the lift spring bracket located on front half of Distiller (fig. F). 2. Be sure gasket on boiler is securely in place. 3.
Installing Saddle Valve on Copper Pipe IMPORTANT: DO NOT use a hot water supply. 1. Assemble saddle valve on COLD water pipe with two (2) bolts (fig. I). Be sure piercing lance does not protrude beyond the sealing washer. 2. Tighten bolts evenly with saddle clamp brackets parallel. DO NOT OVERTIGHTEN. 3. Slide compression nut over end of 1/4” tubing. Place white compression ring on tubing. Be sure wide end of ring is facing compression nut (fig. I). Insert brass tube support into end of tubing.
Utility Faucet Connection (optional) For 3/4” male threaded faucet (fig. J). Installation 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Figure J Turn off COLD water faucet. Disconnect any appliance hose from faucet. Insert rubber washer into brass body. Screw brass body onto faucet. Screw valve into threaded hole on brass body. Tighten with wrench. Slide compression nut over end of 1/4” tubing. Place white compression ring on tubing. Be sure wide end of ring is facing compression nut (fig. J).
DISTILLER MAINTENANCE IMPORTANT: To avoid personal injury, unplug boiler tank cord only after “Fan” and “Power” switches (fig. G) are turned off, Distiller is unplugged from wall outlet, and unit has completely cooled. Boiler Tank Empty the water out of boiler tank after every 15-20 gallons of water distilled or weekly, whichever comes first. To empty boiler, press “Fan” and “Power” switches to “OFF” position. Unplug main power cord from wall outlet. Unplug boiler tank cord.
TROUBLESHOOTING 1. Distiller does not operate. A. Distiller is not plugged into properly rated voltage AC grounded electrical outlet or circuit breaker is tripped. B. “Power” switch is not on. C. Water connection is not open. 2. Boiler tank does not fill with water. A. Water connection is not open. B. “Power” switch is not on. C. Storage reservoir is full. Draw sufficient water out of reservoir to activate float switch. D. Inlet water valve is defective.* E. Water microswitch is defective.* 3.
WARRANTY REGISTRATION CARD Please fill out and return the enclosed registration card or register online at http://www.waterwise.com/customers/customers.asp Registration will not affect warranty coverage but may expedite processing of your warranty. Registration is the only way to guarantee you will be notified by Waterwise of any issues that arise concerning this product.