Owner's Manual
www.adhguardianusa.com
Door Status Activation Using Door Control / Remote Control.
Door at fully open / close position Door will move to fully close / open position.
Door is closing Door will stop. Upon next activation door will reverse to fully open position.
Door is opening Door will stop. Upon next activation door will continue to open if door is
below the electronic limit reference point or close if above the limit reference
point.
Door is obstructed while closing Door will reverse and beep x 25.
Door is obstructed while opening Door will stop and beep x 25.
Door is fully opened and photo eye Door will not close and beep x 20.
safety system is obstructed
Door Status vs. Activation
Operation / Condition Courtesy Light / Buzzer Responses
Opener is initially plugged-in (no travel limits stored see page 14-16) UP and DOWN indicators blink 5 times
Reconnecting power (with travel limits stored) Light On for 4.5 minutes
“LEARN” button is pressed Beep x 1, OK indicator glows
Upon activation Light on for 4.5 minutes
Upon activation by remote controls Beep x 1, Light on for 4.5 minutes
Remote control / keyless entry PIN code stored successfully Beep x 2
Photo eye safety system is obstructed during door-closing Beep x 20
The door is obstructed during travel Beep x 25
Door travels with abnormal speed Beep x 12 (1 beep / second)
The cable tension monitor detects slack that may occur in the cables Beep x 13
The automatic lock door (GU-LOCK2) is disconnected or damaged Beep x 7
Opener is operated without programming Beep x 5
Courtesy Light / Buzzer Responses
Operating the Opener
WARNING
To prevent SERIOUS INJURY or DEATH:
- Use emergency release to disconnect the motor ONLY when the door is CLOSED to prevent unexpected
rapid falling in case of a unbalanced / poor-conditioned door.
- Use emergency release ONLY when doorway is clear of persons and obstructions.
- DO NOT use emergency release to pull the door open or closed.