Installation Guide

T0073500 Rel-0004
©2020 Caretaker In-Floor Systems
12 of 166-Port
The Caretaker cleaning heads are designed to operate at a specific gallonage and pressure.
To maintain flow through the heads, run the system whenever the pump is on.
Cleaning times will vary according to application and environment. To determine the optimum
cleaning time, run the system 24 hours a day to start. Reduce run times by 2 hours every 2
days until minimum cleaning time is determined. Six hours a day is recommended.
Electrical cost savings can be gained by using a variable speed pump. The pump can be
run through out the day at low RPM's, allowing water rotation through the filtration system.
However, a high speed cleaning session will still be required to clean the floor of the pool.
Fine tune your system by finding the minimum speed required to fully lift the heads.
Cleaning the Filtration System
For optimum cleaning efficiency, routinely clean the pool pump basket, skimmer and filter
screens. Clean the pool filter whenever pressure increases 3 psi above normal clean-filter
operating pressure. Refer to the manufacturer’s instructions of the filter for proper cleaning
instructions.
Changing Cleaning Heads
The cleaning head MUST be in the full down position before removal (see Figure 13).
1. Attach the Head Removal Tool (part number 3-17-8) to the pool pole.
2. Snap tool into the head.
3. Turn counter-clockwise (1/4 of a turn) to release head from collar.
4. Pull and lift head out of collar.
To reinstall, simply insert head into collar and turn clockwise to lock it into position.
Winterizing
1. Remove the cassette assembly. Refer to instructions on Page 11.
2. Remove any cleaning heads located above the freeze line (step or bench heads).
3. Use compressor or blower to blow water from discharge lines.
4. Insert winterizing plugs into ports on the valve bottom or use 2-way valves on each line.
(see page 8)
5. Place winterizing plugs into collars that are above water line to prevent runoff from filling
the lines and refreezing.
Operation and Routine Maintenance
To prevent freeze damage in cold climates, remove water from the feed lines
that are above the freeze line and seal the valve.
CAUTION