User Manual

-
12
-
6.6 Voltage balancing and monitoring during the discharge
The processor monitors the voltage of individual cells during 'storage-mode' and
'discharge' of Lithium battery pack. It tries to normalise the voltages to be equal. For this
feature, the individual plug of the battry pack should be connected to the individual port of the
charger.
If the voltage of any one or more cells varies abnormally during the procedure, It
terminates the process forcibly with the error massage. If this happens, the battery pack
contains the bad cell, or the bad connection of the cable plug. You can easily know which one
cell is bad by pressing INC button at time of showing the error message.
6.4 'STORAGE' control of lithium battery
This is for charging or discharging Lithium battery not to be used for the time being. The
program will determine to charge or discharge the battery to the certain voltage depending on
the voltage of the battery at its initial stage. They are different from the type of the battery, 3.75V
for Lilo, 3.85V for LiPo and 3.3V for LiFe per cell. If the voltage of battery at its initial stage is
over the voltage level to storage, the program will start to discharge
.
At this screen, you can set up the current and the voltage
of the battery pack to be charged. The current will be
used for charge or discharge the battery to reach the
'storage' level of voltage.
The screen shows the present situation during charge
process. To stop charging press Batt type/Stop key once.
6.5 Discharging Lithium battery
The value of discharge current on the left side of screen
may not exceed 1C for a maximum safety and the nal
voltage on the right should not be under the voltage level
that is recommended by the battery manufacturer to
avoid deep discharging.To start to discharge, press Start/
Enter key for more than 3 seconds.
This shows the present state of discharge. To stop
discharging press Batt type/Stop key once.